ASTM D4543 PDF

All the Controls products ASTM D standard. Enter now!. Designation: D – 85 (Reapproved )e1. AMERICAN SOCIETY FOR TESTING AND MATERIALS Barr Harbor Dr., West Conshohocken, PA ASTM De1 [ Withdrawn ]. Standard Practices for Preparing Rock Core as Cylindrical Test Specimens and Verifying Conformance to.

Author: Kigashakar Nesida
Country: Mexico
Language: English (Spanish)
Genre: Life
Published (Last): 22 June 2014
Pages: 66
PDF File Size: 4.36 Mb
ePub File Size: 7.82 Mb
ISBN: 993-3-28924-266-6
Downloads: 71999
Price: Free* [*Free Regsitration Required]
Uploader: Vihn

Concrete – Specimen grinding machine: It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine astj applicability of regulatory limitations prior to use.

Link to Active This link will always route to the current Active version of the standard.

ASTM D, Test equipment Controls

Follow us YouTube LinkedIn. Specimen grinding machine Used to grind and polish concrete specimens, natural stones, ceramic materials, etc. Home Products Search results Results for: For curatorial issues that should be followed ashm and during specimen preparation refer to Practices D and to the specific test standards in 2.

This document cannot replace education or experience and should be used in conjunction with professional judgement.

Most commonly, this situation ast, itself with weaker, more porous, and poorly cemented rock types and rock types containing significant structural features.

Rock specimen grinding machine Used to grind and polish rock and concrete specimens, natural stones, ceramic materials, etc. However, some of the information contained with in this practice and in standard Test Method C may still be of use to preparing other test specimen shapes.

As such, it is not always possible to obtain or prepare rock core specimens that satisfy the desirable tolerances given in this practice. These practices specify procedures for laboratory rock core test specimen preparation of rock core from drill core and block samples for strength and deformation testing and for determining the conformance of the test specimen dimensions with tolerances established by this practice.

  CANON RS-60E3 MANUAL PDF

This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project’s many unique aspects. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Rock mechanics – Sample preparation equipment: Iva Company info Privacy policy The word “standard” in the title of this document means only that the document has been approved through the ASTM consensus process.

Best effort in surface preparation refers to the use of a well-maintained surface grinder, lathe or lapping machine by an experienced operator in which a reasonable number of attempts has been made to meet the tolerances required in this procedure.

For these and other rock types which are difficult to prepare, all reasonable efforts shall be made to prepare a specimen in accordance with this practice and for the intended test procedure. Combining values from the two systems may result in non-conformance with the standard. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

Link to Active This link will always route to the current Ast, version of the standard. However, when it has been determined by trial that this is not possible, prepare the rock specimen to the highest standard practicable and consider this to be the best effort and report it as such, with all appropriate size and dimensional measurements reported as in Section 6.

  ALGORITHM DESIGN KLEINBERG PDF

Suitable to grind up to 2x mm concrete cubes, 2x x mm concrete cylinders, 2x or 4x rock Not all aspects of this practice may asttm applicable in all circumstances.

Active Risk Management

This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a d45543 many unique aspects.

Bench model version with central grinding head and horizontal movable d45443 platform. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.

The SI units given in parentheses are for information only.

Stay on Page Continue to Compass. Most commonly, this situation presents itself with weaker, more porous, and poorly cemented rock types and rock types containing significant or weak or both structural features.

However, the use of balances or scales recording pounds of mass lbm shall not be regarded as nonconformance with this standard. Rock sample verification apparatus Used to verify the dimensional and shape tolerances of rock core specimens up to 75 mm dia.

In addition, they are representative f4543 the significant digits that generally should be retained. Specimen grinding machine The machine is used to grind and polish rock and axtm specimens, natural stones, ceramic materials, etc.